Model Number Frequency Range
(GHz)
Rated Power
(watts min.)
P1dB Power
(watts min.)
Gain
(dB min.)
Mains
(kVA)
Weight
(lbs.)
Size (Inches)
(W x D x H)
T3027-120 27.5 – 30.0 120 60 51 1.0 45 19 x 24 x 5.25
T3027-150 27.5 – 30.0 150 75 52 1.2 45 19 x 24 x 5.25
T3027-250 27.5 – 30.0 250 125 54 1.5 75 19 x 25.25 x 8.75
T3127-250 27.5 – 31.0 250 125 54 1.5 75 19 x 25.25 x 8.75
T3127-400 27.5 – 31.0 400 200 56 3.5 180 19 x 25.25 x 14
T3130-120 30.0 – 31.0 120 60 52 1.2 45 19 x 24 x 5.25
T3832-40 32.0 – 38.0 40 20 46 0.8 45 19 x 24 x 5.25
T3832-60 32.0 – 38.0 60 30 48 0.9 45 19 x 24 x 5.25
T3832-80 32.0 – 38.0 80 40 49 1.0 50 19 x 24 x 5.25
T4540-70 40.0 – 45.0 70 30 49 1.5 80 19 x 25.25 x 10.5


IFI T-MM Series TWT Amplifier Specifications

  • Input/output Impedance: 50 ohms
  • RF Input/ Sample Connectors: Type K Female, unless specified otherwise
  • RF Output Connector: WR28 for frequencies from 27.5 – 38.0 GHz an WR22 for 40 – 45 GHz Other waveguides available by request or specification (see Option 117)
  • Input VSWR: 2.0:1
  • Output VSWR: 2.5:1
  • Operating Temp: 0º to 50º C
  • Non-operating Temp: -40º to 70º C (50,000 feet max)
  • Humidity: 95% without condensation
  • Altitude: 10,000 feet
  • Cooling System: Air cooled, self contained
  • Modulation: All types, AM, FM, Pulse
  • Configuration: Rack Mount as specified in Model Table, or Cabinet Integrated as needed
  • Spurious Outputs: <-60 dBc nominal
  • Standard Prime Powers:
    100, 115, 120 VAC ±10% 50/60 Hz, single phase
    200, 220, 230, 240 VAC ±10% 50/60 Hz, single phase
    100/200VAC,115/208 or 200/220/230/240 VAC ±10% 50/60 Hz, three phase Wye or Delta and/or 400 Hz power is available.

    • Special Prime Powers other then listed are subject to availability